Assistance 4D probe; realize the probe through the ID code; change the 4D push sign by way of the electrical relay for making the 4D probe get the job done Typically. 4.two.two Major board The main board could be divided into two parts: entrance-finish of the primary board and back-close of the leading board.
Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.
Never use any cables aside from the cables furnished with the machine by Mindray. three. Use the cable supplied with This method to connect the printer. Other cables could cause electric powered shock. Site 15: Mechanical Protection
three. Click the higher icon while in the screen (prompts “Update” if you set the cursor on it), the update action is performed, if fails, remember to send out to R&D center. Determine six-one Principal Check Servicing Monitor 4. Just after update is prosperous, restart the equipment just after electrical power off to help make the information powerful. HDD Partition ... Page 91 structured report related info file and DICOM viewing application Report report template obd.bin OBD information file version.txt Variation file Remark Comment file AnatomyImage Anatomical photographs Measurement Measurement library Doppler application and similar boot configuration main file and plug-ins, distant desktop server Multilanguage string file exe videoplay.
By continuing your stop by on our Internet site, you will be consenting to our usage of cookies. Having said that, you can alter your cookie configurations at any time. Cookie desire Acknowledge and Move forward
Page a hundred forty five Clean up user interface Resources: dry gentle cloth, mild soapy h2o Process: Use dry smooth cloth to scrub the area in the process. Should the method is dirty, moisten the delicate fabric with moderate soapy h2o and wipe off any stains. Use dry delicate fabric to get rid of any humidity and permit all tricky surfaces to totally air-dry. Page 146: Thoroughly clean The Peripherals
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
S. ought to supply the Division having an e-mail tackle if they have got a single. The e-mail presented might be useful for official communication Along with the licensee. Even so electronic mail addresses are public file. If you don't desire to provide a private handle, please supply the Division having an electronic mail deal with which may be produced accessible to the public. To find out When you are a licensee below Chapter 455, File.S., please Click this link . Item Acceptance Accepts:
Be aware: Before uploading the log, make sure the ultrasound procedure is connected to community, if not, the program could warn “couldn't connect with server” The server (smtp.
The chapter materials the strategy to confirm primary perform and functionality of product or service. This is certainly only employed for reference, not preventive execution. Operate examining and testing of the component shall be performed by Mindray support engineers along with the user alongside one another. Page 66: Normal Exam
Be aware: About the watch, the brightness adjustment arrives right before contrast. After readjusting the keep track of’s distinction and brightness, alter all preset and peripheral settings.
Notice: Before inserting the connector to the probe port, inspect the connector pin. If your pin is bent, don't use the probe right up until it has been inspected / fixed / replaced. Installing Peripherals With the products from the supported peripherals, remember to refer to “two.
Soon after replacing the CPU module, important file has to be created once again based on the new MAC handle and created into HDD of the machine. Or else, the configuration functionality of your product or service is going to be lost. Soon after getting rid of the CPU module, Eliminate panhead screws with washers (12 M3X6) set on the leading device box, you can take from the board. Webpage 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Maintain the higher fringe of user interface assembly, and open Dp50rb up up the user interface. Determine eight-30 Disassemble the Control Panel Assembly (two) Following eliminating just one countersunk head self-tapping screw PT3X10 fastened over the control panel and take out the plug on the keyboard and the key device connecting cables, you might take out the user interface assembly.
Effectiveness Check 5.five.one Check Course of action Resolution Detection depth Geometric Place Accuracy Blackout space check File the Test pictures 5.5.two Check Information The graphic made use of here is only for reference, keep on with the graphic effect in the real Be aware: circumstance. Necessities: Display screen: established the contrast and brightness with the medical application value (or the default status) Procedure natural environment: dim place, simulating the medical application environment. Page seventy six In affliction the transverse resolution testing targets are horizontally exhibited, report the nominal distance of two targets which might be Plainly acknowledged. Repeat the Procedure earlier mentioned to the transverse resolution testing targets at other depths. As revealed in figure down below. Axial resolution ... Site 77 When using the convex probe, keep the transverse resolution screening targets to notice: be displayed close to the midline. When employing a linear probe with steer operate, do not turn on the steer functionality when execute the transverse resolution exam. Zoom while in the area where the targets Situated if vital. The diameter in the concentrate on stage at a specific depth is equal for the transverse resolution in the depth. Page seventy eight 5.
Mindray respects your privateness. We use cookies for many different uses, for instance Web-site performance, enhancing your experience of our Web-site, developing integration with social websites and aiding focus on our marketing.
five.2.3 Geometric positioning accuracy Longitudinal geometric positioning precision Exam Stage: Do adjustments as the way in testing the maximum depth. History the distance by 20mm Every segment over the longitudinal targets line utilizing the measurement caliper; Choose the worth with the greatest mistake (to 20mm), determine the precision using the method down below The measurement caliper should be positioned for the upper edge of the focus on, Be aware:... Web site 79 Transverse geometric positioning precision Take a look at Step: Go over the scan surface area on the phantom with drinking water or couple gel, gently Call the probe Along with the scan surface area Adjust the depth, earning the transverse targets to become shown within the image. Regulate the focus point to generally be posited beside the transverse targets (the normal is just not very clear) Modify parameters like achieve, TGC, earning Every transverse targets to get Plainly displayed. Page eighty 5.5.two.4 Blackout Spot Check Phase: Protect the scan surface area of the phantom with h2o or pair gel, Carefully Speak to the probe While using the scan floor Alter the depth at a lessen value, and set the main focus at the nearest location to the scan floor. Lower the worth of parameters like AP, Obtain until the qualifications sounds just is often seen. Page eighty one: Application Enhance And Maintenance